USB PD 5–28 V fixed, PPS and AVS with a display and three-button control.
Specifications
| Output | PD 5–28 V · fixed / PPS / AVS |
|---|---|
| Buttons | ON · K1 · K2 |
| Voltage step | 20 mV / 100 mV / 500 mV / 1 V |
| Current step | 50 / 100 / 500 / 1000 mA |
| Monitor IC | INA226 |
| Protocols | USB PD · QC · AFC |
Highlights
Web tools
PDTriggerMonitor and FirmwareUpdater require no installation.
Profile memory
The output profile can be restored on power-up.
Three buttons are provided: ON, K1 and K2. A short press changes page; a long press opens the menu. Voltage steps are 20 mV / 100 mV / 500 mV / 1 V; current steps are 50 / 100 / 500 / 1000 mA.
The interface has three pages: base (voltage, current and bar graph), detail (mAh, mWh and temperature) and peaks. Settings include brightness, idle blanking, 180° rotation, output restore on power-up, and the INA226 conversion time and averaging count.
Two browser-based tools are provided and require no installation: PDTriggerMonitor for live curves, and FirmwareUpdater for .fpk firmware over USB.